AeroLoop · Engineering note
AeroLoop investigates a contact point five metres away
Twelve three-second Isaac GPU probes completed. Both default 1.25 ms repeats report a contact point 4.898484 m outside the vehicle collider, with a positive impulse along a downward normal.
Source: https://louijiecompo.com/updates/aeroloop-contact-probe/
Inspect the retained contact measurements
Twelve three-second Isaac GPU probes completed. Both default 1.25 ms repeats report a contact point 4.898484 m outside the vehicle collider, with a positive impulse along a downward normal.
A comparison setting, not a physics fix
Default per-iteration, 1.25 ms: 1 negative interval in each repeat.
Peak reported distance outside the collider: 4.898484 m. Minimum aggregate normal Z: -0.06032943 N.
The distant report repeats. Its physical interpretation remains unresolved.
Inspect coordinates, impulse and all twelve results
Vehicle COM: 0.002998, 0.009127, 0.052402 m. Reported contact: 5.101453, -0.190759, 0.001000 m.
Scalar impulse: +0.00007541179 N s. Normal approximately (-0.00041095, 0, -0.99999994). Aggregate normal Z: -0.06032943 N. Normal reconstruction error: 1.908 × 10^-12 N s.
| Case | Intervals | Negative intervals | Peak distance outside / m |
|---|---|---|---|
| per-iteration-dt5000-r1 | 600 | 0 | 0.000338 |
| per-iteration-dt5000-r2 | 600 | 0 | 0.000338 |
| per-step-dt5000-r1 | 600 | 0 | 0.000333 |
| per-step-dt5000-r2 | 600 | 0 | 0.000333 |
| per-iteration-dt2500-r1 | 1200 | 0 | 0.000167 |
| per-iteration-dt2500-r2 | 1200 | 0 | 0.000167 |
| per-step-dt2500-r1 | 1200 | 0 | 0.000169 |
| per-step-dt2500-r2 | 1200 | 0 | 0.000169 |
| per-iteration-dt1250-r1 | 2400 | 1 | 4.898484 |
| per-iteration-dt1250-r2 | 2400 | 1 | 4.898484 |
| per-step-dt1250-r1 | 2400 | 0 | 0.000083 |
| per-step-dt1250-r2 | 2400 | 0 | 0.000083 |
Evidence boundary. Diagnostic simulation only. Measurement consistency does not establish solver cause or physical validity. Original flight rejection and AL-010 remain open.
Only the public summary is retained here. This is not a new GPU run or playback of the upstream raw captures. The per-step setting is deprecated and remains diagnostic.
Numerical report · JSON · Source validation record · Figure provenance and hashes
Inspect the pinned source (opens in a new tab) ↗ · Read the contact investigation →
PR #32 investigates the negative contact measurement with three timesteps, two force-integration settings and two repeats. All twelve declared probes completed; six repeated pairs match across every captured field. The independent arithmetic audit covers 16,800 intervals.
At 2.31875 s, both default 1.25 ms probes retain a positive scalar impulse along a downward geometric normal and a contact point 4.898484 m outside the oriented vehicle collider. Reconstructed impulse, sensor output and measured linear momentum agree within the reported errors. Shared backend APIs do not provide independent physical validation.
The deprecated per-step comparison does not reproduce that incident in this cohort. It is diagnostic, not a recommended default change. The original 50-second flight remains rejected. Three-second probes do not evaluate mission acceptance or resolve contact-physics convergence.
Explore the topic
Follow the evidence
Read source evidence ↗ (opens in a new tab)
Related reading
- One Experiment, Two Physics Engines: Comparing MuJoCo and Gazebo Without Assuming They Agree
- Why Did the Physics Engine Report Contact Five Metres Away?
- Why a Drone Landing Physics Audit Still Couldn't Prove Convergence
- Why 15 of 18 Drone Missions Passed but the Controller Still Failed Acceptance
- The Drone Missed the Landing Before It Touched the Ground
- How Long Can a Drone Controller Fly Blind? Measuring Recovery From Sensor Outages
Follow writing and engineering notes
Add this feed to your RSS reader to follow new articles and engineering notes. No signup or tracking on this site.
Follow via RSS